Extension leads and adaptors: the items most likely to fail

The lead under the desk is often the least cared-for item in the building and the one doing the most work.

Updated 24 September 2026 · Checked against HSE and government guidance

Extension leads get moved, trodden on, overloaded and plugged into each other, so they fail more often than most appliances. HSE treats them as portable equipment in their own right, to be checked and tested like anything else. Keep the total load on any lead under 13 amps, do not plug one lead into another, and unwind cable reels fully before running anything heavy.

Why leads fail

These are the faults that turn up most often on extension leads and adaptors:

  • damage to the outer sheath of the cable, often where it has been trapped under a desk leg or a door
  • cable pulled loose where it enters the plug, so the coloured inner wires are visible
  • cracked sockets or plugs
  • scorch marks or discolouration, a sign of overheating
  • tape used to repair or join cables
  • a nail, foil or wire in place of a fuse

Every one of these is visible. A weekly glance at the leads in each room catches most of them before they become dangerous.

Overloading

A standard four-way extension lead is rated at 13 amps in total, not 13 amps per socket. That is roughly 3,000 watts. A kettle alone can use most of it, so a kettle and a heater on the same lead is an overload. Check the wattage on each item's rating plate and add them up. Electrical Safety First has a free online socket overload calculator that does the sums for you.

Daisy-chaining

Electrical Safety First's advice is one extension lead per wall socket, never one plugged into another. Daisy-chaining stacks more load onto the first lead and the wall socket. If you are doing it because there are not enough sockets, that is a sign the room needs more sockets, which is a job for an electrician.

Cable reels

A cable reel only reaches its rated current when it is fully unwound. Wound up, the cable cannot shed heat, and Electrical Safety First warns that running a reel in its wound state can make it overheat and catch fire. Unwind it completely before running a heater, a pressure washer or power tools, and choose reels with a thermal cut-out.

Block adaptors

Plug-in block adaptors sit directly in the wall socket, where their weight and the leverage of the plugs in them can loosen the connection and make it run hot. A bar-type extension lead on a cable avoids that. If you do use a block adaptor, choose a fused one and keep the load low.

How leads are tested

HSE treats extension leads, multi-way adaptors and connecting leads as portable appliances. They get user checks, a formal visual inspection and a combined inspection and test, at intervals that depend on what they supply and where. At a test visit, each lead is counted and labelled as its own item, and surge-protected strips count as leads too.

Need a test? Up to 50 items is £50, all-inclusive with no VAT to add, and your certificate is emailed the same day. See pricing or book online.

Sources

Common questions

Do extension leads need PAT testing?

Yes. HSE treats extension leads, multi-way adaptors and connecting leads as portable equipment, with user checks, visual inspections and testing like any other item.

How much can I plug into a four-way extension lead?

No more than 13 amps in total, which is about 3,000 watts across all four sockets. A kettle or a heater can use most of that on its own.

Is a surge protector the same as an extension lead?

For testing purposes, yes. It is counted and tested as a lead. The surge protection does not stop it being overloaded or damaged.

Ready to get tested?

Pick a slot in the next four weeks, or send us the details for a date further out. It's a provisional booking, and one of the team will be in touch to confirm.